ADA Compliant Fixtures
Lumenelle fixtures labeled as ADA Compliant are designed to portrude less than 4" from the wall to comply with...
ADA Standards for Accessible Design,  28 C.F.R. Part 36,  Appendix A,  4.4 Protruding Objects.
4.4.1  General. Objects projecting from walls with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100 mm) into walks, halls, corridors, passageways, or aisles.
Other ADA considerations for light fixtures...
4.4.1 (cont) Free-standing objects mounted on posts or pylons may overhang 12 in (305 mm) maximum from 27 in to 80 in (685 mm to 2030 mm) above the ground or finished floor. Protruding objects shall not reduce the clear width of an accessible route or maneuvering space.
ADA considerations for hanging light fixtures...
All fixtures hanging above walks, hallways, corridors, passageways, aisles, and lobbies cannot hang down below a height of 80 inches above the ground or finished floor, unless there is a cane-detectible barrier that would alert a person who is blind or who has low vision to the hazard.
4.4.2 Head Room Walks, halls, corridors, passageways, aisles, or other circulation spaces shall have 80 in (2030 mm) minimum clear head room. If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided.
ADA considerations for light fixtures located near elevators...
ADA Standards for Accessible Design,  28 C.F.R. Part 36,  Appendix A,  4.10 Elevators.
4.10.11 Illumination Levels. The level of illumination at the car controls, platform, and car threshold and landing sill shall be at least 5 footcandles (53.8 lux).